摘要: |
炼油厂汽提废水含较高的酚和COD,会对污水处理场产生冲击。采用曝气生物滤池法对其进行处理,取得了满意的结果。当水力停留时间为2.0h,处理后出水的酚和COD平均浓度分别为8.5mg/l和140mg/l,平均降解率分别大于90%和70%,完全可以消除它们对污水处理场的冲击。 |
关键词: 曝气生物滤池 废水处理 炼油厂 汽提废水 中试 酚 净化装置 |
DOI: |
分类号:X742 |
基金项目: |
|
Pilot - Plant Test of Treatment Wastewater from Stripping Tower with Biological Aeration Filter |
Zhong Huawen Liao Yan Zhang Junzheng et al
|
Abstract: |
Wastewater produced from stripping tower, containing high strength phenol and COD, can bump against wastewater treatment facility. The satisfactory results have been obtained with biological aeration filter: Under the hydraulic retention time of 2. Oh, th |
Key words: pilot-plant, phenol, stripping tower's wastewater, biological aeration filter, |