摘要: |
南阳油田某净化站是一套气体净化、液化气处理装置,生产中发现有结垢现象出现。系统压降较大,影响了设备的正常运转,同时引发了严重的垢下腐蚀。分析结果表明,结垢原因与原料气所含地层水关系不大,结垢主要由酸气腐蚀和细菌腐蚀引起,并提出了相应的防垢建议。 |
关键词: 净化站 结垢 腐蚀 |
DOI: |
分类号:TE319 TQ085.4 |
基金项目: |
|
Scale Deposit Analyzing in a Purifying Station of Nanyang Oilfield |
Gu Tan~1 Liang Gengbai~2 Li Feng~3 et al
|
Abstract: |
Scales was found in a set of installation for gas clarification and LPG treatment in a purifying station of Nanyang Oilfield. The scales caused greater pressure drop and interfered with the operation of the system.Additionally, scales corrosion was taken |
Key words: purifying station, scale deposit, corrosion |