摘要: |
利用PRO/II软件分析了某0.6 Mt/a气体分馏热泵流程用能情况,优化了气分装置热泵系统的工艺参数,计算了各设备的有效能效率。利用夹点技术对其换热网络进行了优化,在不增加设备投资费用的基础上节省加热公用工程量712.29 kW,冷却公用工程量712.29 kW,具有较好的节能效果。 |
关键词: 热泵精馏 气体分馏 有效能分析 夹点技术 |
DOI:10.3969/j.issn.1007-3426.2015.05.024 |
分类号:TE683 |
基金项目:陕西省教育厅专项科研计划项目资助“柴油深度脱硫无负载纳米多金属硫化物催化剂”(14JK1563)。 |
|
Energy consumption analysis of heat pump drived distillation gas fractionation unit |
Zhu Yuqin, Zhang Hairui
|
(Xi’an Shiyou University, Xi’an 710065, China)
|
Abstract: |
The energy-use state was analyzed on the heat pump process in a 0.6 Mt/a light-ends unit with the process simulation software PRO/II. The pinch point technique was used to optimize the parameters of the heat-exchange system drived by heat-pump and the energy efficiency of some key equipment was also calculated. The majorization induced favorable energy saving effects and resulted in saving heating and cooling as high as 712.29 kW and 712.29 kW, respectively. |
Key words: heat pump distillation gas fractionation exergy analysis pinch point technique |